Test modes and typical applications
| Test mode | Typical application |
| Pressure decay | Leak tightness of test parts |
| Pressure rise | Leak tightness of combined chambers |
| Dynamic pressure | Continuity test |
| Pressure steps | Opening point of valves |
| Closed component | Leak tightness of sealed test parts |
| Volume measurement | Determination of test part volumes |
| Mass flow | Leak tightness of test parts with large volume and small rates |
| Flow | Flow though pipes |
Overview test data and test ranges
| Test data | Range |
| Test pressure | -1 bar ... 300 bar |
| Measurement range | 400 Pa ... 30.000 Pa |
| Resolution | 1 Pa |
| Test part volume | 0,1 ml ... 10.000 ml |
| Leak rate | 0,6 ml/min ... 10 ml/min |
| Total test time | 1 s ... 100 s (depending on test part volume) |
Typical applications
- Testing for oil-tightness or watertightness
- Leak testing according the requirements of the IP protection classes
- Testing of enclosures (e.g. gear box cover, reservoires, shiners)
- Testing of coolers, gear boxes (inner and outer leak tightness)
- Leak testing of parts with venting elements (e.g. membranes)
- Testing of sensors, clocks, micro electronic devices (closed components)
- Testing of elements with hydraulics (e.g. shock absorbers, servo pumps)
- Continuity test of pipes and valves
- Determination of the opening and closing point of valves
- Flow test of pipes, valves, membranes, exhaust-gas sysytems