> Information  > Applications

Test modes and typical applications

Test mode Typical application
Pressure decay Leak tightness of test parts
Pressure rise Leak tightness of combined chambers
Dynamic pressure Continuity test
Pressure steps Opening point of valves
Closed component Leak tightness of sealed test parts
Volume measurement Determination of test part volumes
Mass flow Leak tightness of test parts with large volume and small rates
Flow Flow though pipes

Overview test data and test ranges

Test data Range
Test pressure -1 bar ... 300 bar
Measurement range 400 Pa ... 30.000 Pa
Resolution 1 Pa
Test part volume 0,1 ml ... 10.000 ml
Leak rate 0,6 ml/min ... 10 ml/min
Total test time 1 s ... 100 s (depending on test part volume)

Typical applications

  • Testing for oil-tightness or watertightness
  • Leak testing according the requirements of the IP protection classes
  • Testing of enclosures (e.g. gear box cover, reservoires, shiners)
  • Testing of coolers, gear boxes (inner and outer leak tightness)
  • Leak testing of parts with venting elements (e.g. membranes)
  • Testing of sensors, clocks, micro electronic devices (closed components)
  • Testing of elements with hydraulics (e.g. shock absorbers, servo pumps)
  • Continuity test of pipes and valves
  • Determination of the opening and closing point of valves
  • Flow test of pipes, valves, membranes, exhaust-gas sysytems

Language selection

Deutsch
English

Download

Accessories

Here you can find information about the application software CETA Soft and other accessories for CETA test devices... [more]

News

Here you can find up-to-date announcements, our exhibition calendar and other appointments as well as press releases... [more]

FAQ

In our "FAQ" section you can find answers to the most frequently asked questions... [more]