> Products  > Leak Detectors > Leak Detector CETATEST 510

Leak Detector CETATEST 510

The CETATEST 510 is a full automatically working leak detector for the detection of untight parts within the cycle time of the production process. The leak detector is available in three different types: The configuration “closed components - high resolution” can be used for test parts, which can not be filled, so called “closed components”. It is possible to detect very small ratios of test part volumes. The type “pressure loss - high speed” can be used for leak tests of very small test parts in high speed production cycles. The configuration “pressure rise” has a very high measurement signal and integrated components (e.g. stop valve, primary pressure control).

 

 

[zoom] For a detailed view please click on the picture

Sensor type Piezo-resistive differential pressure sensor
Measurement range 400 Pa in 1 Pa-Steps
Result units Pa, Pa/s, ml/min, ml/h
Pressure controller electronical (primary pressure), mechanical (secondary pressure, type “pressure rise”)
Test pressure sensor Piezo-resistive gage pressure sensor
Test pressure ranges Negative gage pressure, 200 mbar, 1 bar (type “pressure rise”: up to 100 bar)
Test modes Pressure loss measurement, test of closed components in high resolution (option A), high speed pressure loss measurement (option B), pressure rise measurement (indirect) (option C)
Dimensions 345 mm x 145 mm x 435 mm (W x H x D)
Typical applications Tests of micro switches, sensors, relays, valves, watches

Language selection

Deutsch
English

Download

Certifications

The CETA Testsysteme GmbH has achieved different certifications. Here you can find an overview... [more]

Accessories

Here you can find information about the application software CETA Soft and other accessories for CETA test devices... [more]

DKD Calibration for Pressure

In the accredited calibration labor [DKD-K-36001] calibrations for pressure (range: -1 bar to +17 bar) are possible… [more]