Mass Flow Tester CETATEST 610
The CETATEST 610 is a full automatically working leak detector using a mass flow sensor (calorimetric method). It can be used for the detection of untight parts within the cycle time of the production process. The mass flow caused by a leak is measured and is displayed in Norm-ml/min. Temperature effects are automatically compensated during the conversion of the measured mass flow.
| Sensor type | Calorimetric mass flow sensor |
| Measurement range | 50 Nml/min in 0,01 Nml/min-steps (highest resolution depends on the type of the mass flow sensor). The measurement range can be extended by the use of a laminar bypass. |
| Result units | Nml/min (Nml = Norm-ml) |
| Pressure controller | Electronical, mechanical |
| Test pressure sensor | Piezo-resistive gage pressure sensor |
| Test pressure ranges | 1 bar, 10 bar |
| Test modes | Mass flow |
| Dimensions | 345 mm x 145 mm x 435 mm (W x H x D) |
| Typical applications | Test parts with large volumes and small leak rates |